Electricity-use estimate
1,000 kWh × 400 g CO₂e/kWh = 400,000 g CO₂e = 400 kg CO₂e.
The result inherits the boundary, gas basis, time period, and loss treatment of the factor entered.
Electricity emissions (kg) = electricity used (kWh) × grid intensity (kg/kWh)Electricity from average load (kWh) = average load (kW) × operating time (hours)Grid carbon intensity (g/kWh) = total grid emissions (g) ÷ electricity generation (kWh)Useful identity: 1 g/kWh = 1 kg/MWh = 1 metric tonne/GWh. To convert lb/MWh to g/kWh, multiply by 0.45359237. To convert g/kWh to lb/MWh, divide by 0.45359237.
Interpretation limit: This tool performs arithmetic and unit conversion; it does not fetch live grid conditions or decide which accounting factor is appropriate. Formal inventories may prescribe supplier data, residual mixes, contractual instruments, location-based factors, or market-based factors.
1,000 kWh × 400 g CO₂e/kWh = 400,000 g CO₂e = 400 kg CO₂e.
5 kW × 8 h = 40 kWh. At 400 g CO₂e/kWh, emissions are 16,000 g = 16 kg CO₂e.
400 metric tonnes CO₂e ÷ 1,000 MWh = 400 kg/MWh = 400 g/kWh = 881.85 lb/MWh.
An output emission rate is emissions divided by electricity generation. EPA eGRID publishes U.S. plant and regional generation, emissions, and output rates. EPA recommends eGRID subregion total output emission rates for carbon-footprinting electricity purchases because the subregion more closely represents the grid serving a location.
Average rate: use when allocating the emissions of the electricity mix across consumption in a period. Marginal or nonbaseload rate: use only when estimating a change in generation or avoided electricity under a method that calls for it. They answer different questions and should not be mixed without explanation.
For a reproducible result, record the data year, geography, CO₂ or CO₂e basis, average or marginal method, gross or net generation, and whether line losses are included. Do not compare a delivered-electricity factor directly with a plant-output factor without reconciling that boundary.
Convert electricity to kWh and the factor to kg/kWh, then multiply. For example, 1,000 kWh × 400 g/kWh ÷ 1,000 g/kg = 400 kg.
Divide emissions by generation for the same grid, time, and boundary. The result can be shown as g/kWh, kg/MWh, or lb/MWh.
Yes. A value of 400 g/kWh is exactly 400 kg/MWh. It converts to about 881.85 lb/MWh.
Use a recent source that matches the location, reporting period, emissions scope, and purpose. For U.S. electricity footprints, EPA recommends an eGRID subregion total output emission rate.
Average intensity allocates emissions across all generation. Marginal or nonbaseload rates estimate generators likely to respond when demand changes. Neither is universally interchangeable with the other.
Only if the factor entered includes them. The calculator does not apply a hidden loss adjustment.
No. CO₂ covers carbon dioxide; CO₂e expresses several greenhouse gases on a common warming basis. Select the basis published by your source.
Use it as an arithmetic and unit-conversion aid. Follow the required standard for location-based and market-based data, certificates, residual mixes, losses, and documentation.
No. Calculation, copying, and CSV export happen locally in your browser.